Driver |
Dispositivi Supportati |
Requisiti |
Win32/64 |
WinCE |
Download Help *** |
Allen Bradley DF1 |
Rockwell Allen Bradley PLC-5, SLC-500, MicroLogix, ControlLogix, CompactLogix and FlexLogix
|
AB communication interface for multi-drop communication |
x |
x |
|
Applicom |
Various protocols supported by the APPLICOM card |
APPLICOM communication board, APPLICOM library |
x |
|
|
BACnet/IP |
Devices that support the BACnet/IP protocol |
- |
x |
|
|
Beckhoff ADS TwinCAT |
Beckhoff TwinCAT Systems |
Beckhoff ADS software library |
x |
x |
|
Bosch Rexroth MLPI |
Bosch Rexroth devices that support MLPI interface technology. |
The PLC requires a Bosch Rexroth library, dllmlpiwin32.dll, to complete the connection. The dllmlpiwin32.dll file must be present in the Supervisor directory or in a directory included in the โpathโ environment variable. |
x |
||
B&R PVI |
B&R Devices |
B&R PVI Libraries, Standard Ethernet or Serial Cable |
x |
x |
|
CEI-ABI ElMo Ethernet ** |
IEC protocol based on specifications 79/5 and 79/6, ELMO control unit with Ethernet interface |
Standard Ethernet cable |
x |
|
|
CEI-ABI ElMo Serial ** |
IEC protocol based on specifications 79/5 and 79/6, ELMO control unit with Ethernet interface |
RS-232, RS-422 or RS-485 serial connection |
x |
|
|
CEI-ABI Notifier ENet Ethernet ** |
IEC protocol based on specifications 79/5 and 79/6, NOTIFIER Am-2000/AM-6000 control unit |
E-NET and ETH-C CPU Module |
x |
|
|
CEI-ABI Notifier Serial ** |
IEC protocol based on specifications 79/5 and 79/6, NOTIFIER Am-2000/AM-6000 control unit |
RS-232 or RS-485 serial connection |
x |
|
|
CoDeSys |
3S Software CoDeSys SoftPLC versions 2.3 and 3. |
To establish connection with PLC, you need to run a valid program and export the program symbols |
x |
Available for WEC7 only |
|
Control Techniques Modbus |
All devices communicate using standard Modbus serial protocol and Control Techniques drives support both Modbus serial protocol and CMP protocol. |
- |
x |
x |
|
Control Techniques Modbus TCP |
All devices communicate using standard Modbus serial protocol and Control Techniques drives support Modbus TCP and CMP protocols. |
- |
x |
x |
|
COSTER C-BUS * |
COSTER devices that support the C-BUS protocol. |
- |
x |
|
|
CTI TCP |
CTI 2500 Series Programmable Controllers. |
- |
x |
x |
|
Digit Italia ** |
- |
- |
x |
|
|
ELKRON MP100 ** |
- |
- |
x |
||
Elkron DigitItalia ** |
Digit Italia Control Unit |
RS-232 or RS-485 serial connection |
x |
|
|
Emerson SRTP |
Emerson/GE 90 Series PLCs. |
- |
x |
x |
|
Energy Manager RMS621 ** |
- |
- |
x |
||
EtherNet/IP |
The EtherNet/IP protocol is supported by many independent vendors, however this driver has been tested for the following Allen Bradley PLC series: PLC5E, SLC500 /05 Ethernet, MicroLogix (with NET-ENI, ControlLogix, CompactLogix, FlexLogix5434 |
- |
x |
x |
|
GE-Fanuc |
GE Fanuc PLC 90 series, GE Micro series |
CMM 311 serial communication coprocessor for the 90-30 series or CMM 711 for the 90-70 series |
x |
x |
|
Guardall ** |
Guardall Alarm Units, PX and QX Series |
RS232 serial connection |
x |
|
|
Hilscher Profibus DP Master |
Siemens S7-300 Series, Siemens S7-400 Series, VIPA 200V Series, VIPA 300V Series, VIPA 300S Series, VIPA 500S Series |
The Hilscher MPI interface (Hilscher cards supporting PROFIBUS DP master) must be correctly mounted on the PC/panel. |
x |
x |
|
Hilscher MPI |
Siemens S7-300 Series, Siemens S7-400 Series, VIPA 200V Series, VIPA 300V Series, VIPA 300S Series, VIPA 500S Series |
The Hilscher MPI interface (Hilscher cards supporting PROFIBUS DP master) must be correctly mounted on the PC/panel. |
x |
x |
|
Hilscher Netlink |
Siemens PLCs, S7 series 300 and 400, VIPA PLCs and compatible devices |
Hilscher NetLink cable, SyCon software for configuring Netlink devices |
x |
x |
|
Hilscher MPI |
Siemens PLCs, S7 series 300 and 400, VIPA PLCs and compatible devices |
Hilscher cards supporting PROFIBUS DP master + SyCon software for configuration |
x |
x |
|
Hilscher DPM |
Profibus-DP slave devices, such as digital I/O cards, analog I/O cards |
Hilscher Profibus DP master cards + SyCon configuration software |
x |
x |
|
Hilscher CIFX Fieldbus Multi-Protocol
|
Supported Protocols: AS-Interface, CAN open, CC-Link, CompoNet, DeviceNet, EtherCAT, POWERLINK, PROFIBUS-DP,PROFINET IO RT |
Hitachi EH Series Devices, Hitachi EHV Series Devices
|
x |
x |
|
Hitachi |
Hitachi H-Series Devices |
Dedicated 15-pin cable |
x |
x |
|
Hitachi Ethernet |
Hitachi EH Series Devices, Hitachi EHV Series Devices |
Standard Ethernet cable |
x |
x |
|
IEC 60870-5-101U |
RTU connected to a control station either via RS232 or RS485. |
RS-232 or RS-485 serial connection |
x |
x |
|
IEC 60870-5-104 TCP/IP |
RTU connected to a control station or via TCP/IP network. |
Standard Ethernet cable |
x |
x |
|
IEC 60870-5-104 Server |
All devices that support the IEC 60870-5-104 communication protocol as a control station and are compatible with the interoperability list described in this manual. |
Standard Ethernet cable |
x |
|
|
IEC 61850 MMS Client |
IEC 61850 MMS Server. |
- |
x |
|
|
Johnson Controls 9100 ** |
Johnson Controls DX9100 and TC-9100 devices. |
- |
x |
|
|
Jetter JetIP ** |
The driver can be used to communicate with the following PLCs: Jet Control 241 (JC-241), Jet Control 243 (JC-243), Jet Control 246 (JC-246), Jet Control 647 (JC-647), JetMove |
- |
x |
x |
|
Kernel ** |
Kernel Devices. |
- |
x |
||
KNX EIBUS (Falcon) |
Building automation devices that support EIB |
EIB bus, Konnex system, Falcon libraries, BCU device or EIBNet/IP router |
x |
||
Lenze LecomAB ** |
Lenze frequency converters |
Lecom A/B communication module, RS232 connection or RS485 serial bus or fiber optic connection |
x |
x |
|
LonWorks |
Devices compliant with the LonWorks standard. |
The driver uses an Echelon ActiveX to access the LNS server that stores the network description. The ActiveX and supporting software are installed by the LonWorks configuration software. |
x |
|
|
Memory I/O
|
- |
- |
x |
x |
|
Mitsubishi Melsec A TCP
|
Mitsubishi PLC, A series |
A1SJ71E71N-T Ethernet Module |
x |
|
|
MELSEC-FX Series
|
Mitsubishi MELSEC-FX and MELSEC-FX2N PLCs and compatibles |
RS232/422 converter or Mitsubishi PLC programming cable (built-in RS232/422 converter). |
x |
x |
|
MELSEC FX TCP Series |
Mitsubishi FX3U PLC |
FX3u-ENET Ethernet module, FX Configurator-EN software |
x |
x |
|
MELSEC-Q Serial Format 1 |
Mitsubishi MELSEC-Q PLC |
QJ71C24 communication module |
x |
x |
|
MELSEC-Q TCP |
Mitsubishi MELSEC-Q PLC |
QJ71E71 Ethernet communication module |
x |
x |
|
Modbus Serial |
Serial devices that support the Modbus serial protocol |
Standard Ethernet cable |
x |
x |
|
Modbus Serial Slave |
All communication devices that implement the standard Modbus serial protocol as master. |
Standard Ethernet cable |
x |
x |
|
Modbus TCP/IP |
All devices that support the Modbus TCP/IP protocol |
Standard Ethernet cable |
x |
x |
|
Modbus TCP/IP Slave |
All communication devices that implement the standard Modbus TCP/IP protocol as master. |
Standard Ethernet cable |
x |
x |
|
Moeller SUCOM ** |
Moeller PS4-200, PS300 and PS400 series PLCs |
RS232/485 converter |
x |
x |
|
MQTT Client |
Standard MQTT server (broker) |
- |
x |
||
MTConnect |
Any compatible MTConnect Agent (www.mtconnect.org) |
- |
x |
||
Omron EtherNet/IP |
The EtherNet/IP protocol is supported by many independent vendors, however this driver has been tested for the Omron NJ series PLCs. |
Standard Ethernet cable |
x |
x |
|
Omron FINS Ethernet |
OMRON PLC |
Standard Ethernet cable |
x |
x |
|
Omron FINS serial |
OMRON PLC |
Omron serial cable |
x |
||
Omron Host Link |
OMRON PLC |
Omron serial cable |
x |
x |
|
OVA Dardo plus ** |
OVA DardoPlus emergency lighting controllers |
RS232/RS485 Converter |
x |
||
Panasonic FP Mewtocol |
Panasonic Matsushita NAIS-FP series PLC |
FPWIN GR/PRO programming software for PLC configuration; FP-WEB Server or FP2 ET-LAN unit for Ethernet communication |
x |
x |
|
Phoenix Contact Interbus ** |
Remote devices |
IBS PCI SC/I-T PCI card, Interbus cables, DDI library |
x |
x |
|
Phoenix Contact PLCI |
ILC 1x1 series AXC 1xxx series (FW version 1.x, 2.x) AXC 3xxx series PC WORX RT BASIC/SRT |
- |
x |
Available only with ARMV4I devices - WinCE7 |
|
Phoenix Contact PLCI BTP 2K |
ILC 1x1 series AXC 1xxx series (FW version 1.x, 2.x) AXC 3xxx series PC WORX RT BASIC/SRT |
- |
x |
Available only with ARMV4I devices - WinCE6 |
|
Pixsys Soft-PLC * |
Pixsys LogicLab SoftPLC Devices |
- |
x |
x |
|
Siemens PC Adapter-MPI |
Siemens S7 300 and 400 series PLCs, VIPA PLCs and compatible devices |
Siemens PC adapter or MPI INAT adapter or VIPA green cable or compatible, standard serial plug and cable |
x |
x |
|
Siemens PPI |
Siemens S7 200 and compatible PLCs |
Siemens S7 PPI or compatible PC adapter, standard serial plug and cable |
x |
x |
|
Siemens S7 TIA Portal (Symbolic) |
Siemens S7-1200 Series, Siemens S7-1500 Series |
- |
x |
Available only for OEMs and Italian customers |
|
Saia DATA Mode |
All Saia PCD PLCs, provided they support the S-BUS protocol on the supported communication media, i.e. RS232/RS485 (S-BUS), Ethernet (SOCKET). |
- |
x |
x |
|
Saia Multiport Interface |
PLC Saia PDC |
RS232 cable for PGU mode; Ethernet LAN adapter or USB or RS485 adapter for S-BUS mode; Ethernet LAN adapter for ProfiS-BUS mode |
x |
|
|
Schneider Uni-Telway ** |
Schneider Telemecanique PLCs and devices compliant with the Uni-Telway protocol |
Intelligent RS232/RS485 converter (converter integrated in Schneider programming cable not supported) |
x |
x |
|
Siemens S7 SAPI ** |
Siemens S7 300 and 400 series PLCs and compatible devices |
For MPI and PROFIBUS networks: Siemens CP board (CP5611, CP5613, CP5614), Siemens SAPI-S7 library |
x |
|
|
Siemens S7 TCP |
Siemens PLCs, S7 200, 300, 400 series, VIPA PLCs and compatible devices |
Siemens Ethernet Card |
x |
x |
|
Siemens SINAUT ST1 |
Siemens SIMATIC devices equipped with modules that support the SINAUT ST1 protocol. |
- |
x |
|
|
SNMP Manager |
Devices that support the SNMP protocol and act as SNMP agents |
Standard Ethernet cable |
x |
|
|
SoCom ** |
SoftPLC ProConOS. |
- |
x |
x |
|
VIPA S7 TCP |
Siemens PLC S7 series 200, 300, 400, VIPA system 200V, 300V, 300S |
Standard Ethernet cable |
x |
x |
|
VIPA embedded MPI |
PLC VIPA System 100, 200, 300, Speed7; Siemens S7 300 and 400 series PLCs and compatibles |
Standard Profibus or MPI cable |
x |
Available only with ARMV4I devices |
|
VIPA PROFIBUS DP Slave |
- |
PROFIBUS DP Master configured to communicate with a Slave with the appropriate Input/Output modules |
x |
Available only with ARMV4I devices |
|
WITS |
EDR (Electronic Data Recorder) system |
- |
x |
|
|
Yaskawa MPiec Modbus |
All devices communicate using the standard Modbus TCP protocol: Yaskawa devices, PLCs, remote terminal units, analyzers, I/O modules, sensors, controllers, AC/DC drive control devices. |
- |
x |
x |
|
* Third-party drivers are developed by qualified companies using Movicon standard driver base classes. Emerson does not provide any warranty or technical support for these drivers, as it did not participate in their development or testing. For further information, users must contact the third-party developer directly. |
|
** This driver is covered by a limited warranty and may not be fully supported by the Emerson Technical Support Team. Before using it, please verify that the manufacturer still supports the hardware devices or contact Emerson for further information. |
|
***Attention, the driver help will be downloaded locally in .zip format, once unzipped, to correctly read the .chm file inside, it will be necessary to open the file properties -> General and activate the "Unblock" Property of the "Security" group (see image).
|